Adhesive Sterile Breathable Vent For Diagnostic Reagent / Buffer Bottles
Product Details
| Color: | White | Thickness: | 0.10 – 0.50 Mm |
|---|---|---|---|
| Air Permeability: | Gurley:3 – 30 S/100ml @ 300 Ml | Water Entry Pressure: | ≥ 400 KPa |
| Waterproof Rating: | IP68 | Moisture Vapor Transmission Rate: | 8,000 – 18,000 G/m²·24h |
| Oleophobicity Grade: | ≥ 7 | 90° Peel Strength: | ≥ 15 N/25mm |
| Operating Temperature: | -40°C To +150°C | Size: | Customizable |
| Material Compliance: | PFAS Free | Chemical Resistance: | Corrosion-resistant,Acid-resistant |
| Highlight |
Adhesive Sterile Breathable Vent,Diagnostic Reagent Sterile Vent,Buffer Bottles Medical Vent |
||
Product Description
The adhesive sterile breathable vent for diagnostic reagent and buffer bottles is a precision contamination-control component engineered to protect sensitive in-vitro diagnostic (IVD) liquids from microbial contamination and environmental degradation while enabling necessary gas exchange during filling, storage, and dispensing. This vent combines a 0.2-micron sterilizing-grade ePTFE membrane with a medical-grade, low-extractable adhesive backing, designed for direct peel-and-stick application over vent ports in diagnostic reagent bottles, buffer reservoirs, and clinical chemistry analyzer consumables. It provides a sterile, bacteria-retentive barrier that allows pressure equalization during thermal cycling and altitude changes, prevents vacuum formation during liquid aspiration by laboratory instruments, and maintains the reagent's calibrated concentration by preventing evaporative loss and contamination. The vent supports the accuracy and reproducibility of diagnostic test results by ensuring reagent integrity from the manufacturer's filling line to the final aspiration on the clinical analyzer.
In-vitro diagnostic reagents, calibrators, buffers, and control sera are packaged in plastic bottles that interface directly with automated clinical chemistry, immunoassay, and hematology analyzers. These instruments aspirate precise microliter volumes of reagent through a pipetting probe. As reagent is withdrawn, air must enter the bottle to replace the dispensed volume. Without sterile venting, a vacuum develops, causing inaccurate aspiration volumes, air bubbles in the fluid line, and eventually "reagent empty" alarms before the bottle is truly empty—resulting in wasted, expensive reagent and analyzer downtime. Many diagnostic reagents contain proteins, enzymes, or antibodies that are sensitive to oxidation and microbial contamination. An open vent or a non-sterile vent allows airborne bacteria, fungi, and particulates to enter, which can degrade the reagent, cause false-positive or false-negative test results, and generate biohazard concerns. These bottles must also withstand the thermal cycling of refrigerated storage (2-8°C) and room-temperature operation without the vent losing its seal or sterile barrier.
The adhesive sterile breathable vent provides a clean, secure, and easy-to-integrate sterile barrier over the bottle's vent port. The 0.2-micron ePTFE membrane is a recognized sterilizing-grade filter, providing a physical barrier that excludes bacteria, fungi, mold spores, and particulates. As the clinical analyzer aspirates reagent, sterile air is drawn through the membrane into the bottle, instantly equalizing pressure and ensuring accurate, bubble-free aspiration down to the last milliliter. The membrane's hydrophobic property prevents any reagent leakage, even with bottles containing surfactants or low-surface-tension buffer components. The medical-grade adhesive is selected for low extractables and leachables, ensuring that no adhesive-derived compounds contaminate the reagent and interfere with sensitive photometric, fluorometric, or electrochemical detection methods. The vent is supplied on a roll in a die-cut format compatible with automated pick-and-place assembly.
| Parameter | Specification |
|---|---|
| Product Type | Adhesive Sterile Breathable Vent |
| Membrane Material | Medical-grade ePTFE (hydrophobic, low-extractable) |
| Pore Size | 0.2 μm (sterilizing-grade) |
| Bacterial Retention | ≥ 10⁷ CFU/cm² per ASTM F838 |
| Airflow | 100-400 ml/min @ 1 psi |
| Water Entry Pressure | ≥ 80 kPa |
| Adhesive Type | Medical-grade acrylic (low-extractable) |
| Extractables | Meets USP <665> / <1665> for IVD packaging materials |
| Operating Temperature | -20°C to +80°C (refrigerated storage to analyzer operating temp) |
| Installation | Automated pick-and-place, peel-and-stick |
| Sterilization | Gamma, EtO compatible (pre-applied or post-applied) |
| Bottle Compatibility | HDPE, PP, PET, glass |
- Clinical chemistry reagent bottles (enzymatic, colorimetric, ISE reagents)
- Immunoassay reagent and conjugate bottles (chemiluminescent, ELISA)
- Hematology analyzer reagent and diluent containers
- Coagulation analyzer reagent and buffer bottles
- Molecular diagnostics (PCR) master mix and buffer vials
- Urinalysis reagent strip bottle vents
- Blood gas analyzer calibration solution containers
The adhesive vent is applied over a small aperture on the reagent bottle cap or closure during filling and capping. When the reagent bottle is placed on the clinical analyzer and the pipetting probe withdraws reagent, the slight negative pressure draws ambient air through the ePTFE membrane's 0.2-micron pores into the bottle headspace. The membrane allows air to flow freely while physically blocking all bacteria, fungal spores, and dust particles. When the bottle is stored in a refrigerator and then moved to the analyzer's room-temperature deck, the vent allows pressure equalization as the trapped air warms and expands. The hydrophobic membrane prevents any reagent seepage, even with surfactant-containing formulations, while the low-extractable adhesive ensures that no compounds migrate into the reagent over the bottle's shelf life.
- Identify the reagent chemistry and any specific low-extractable requirements per USP or OEM specifications.
- Determine the bottle material and cap design to specify the vent patch dimensions and adhesive compatibility.
- Calculate the required airflow based on the analyzer's maximum aspiration rate and the bottle's headspace volume.
- Select the sterilization method for the final package and confirm vent material compatibility.
- Test the complete bottle assembly for bacterial challenge, extractables/leachables, and functional aspiration performance.
- Q: Will the adhesive leach substances that interfere with spectrophotometric or fluorescence-based detection?
A: The adhesive is a medical-grade, low-extractable formulation. We provide comprehensive extractables data per USP <665> standards for your review and validation. - Q: Can the vent withstand the repeated temperature cycles between cold storage (2-8°C) and the analyzer deck?
A: Yes, the adhesive and membrane are tested for thousands of thermal cycles without loss of bond strength or sterile barrier integrity. - Q: Does the vent prevent the evaporation of volatile buffer components over the reagent's shelf life?
A: The membrane allows minimal gas exchange necessary for pressure equalization. Evaporative loss through the vent is negligible compared to an open port. - Q: Is the vent compatible with aggressive reagents like strong acids, bases, or organic solvents used in some diagnostic methods?
A: ePTFE is chemically inert to most reagents. For aggressive solvents, we can provide a chemically specialized membrane grade. Consult with our team for your specific reagent chemistry. - Q: Can the vent be pre-sterilized and applied aseptically to maintain the sterility of the reagent bottle?
A: Yes, we supply pre-sterilized vents in validated sterile packaging for aseptic application in cleanroom environments.
Product Highlights
Product Overview The adhesive sterile breathable vent for diagnostic reagent and buffer bottles is a precision contamination-control component engineered to protect sensitive in-vitro diagnostic (IVD) liquids from microbial contamination and environmental degradation while enabling necessary gas ...
EPTFE Acoustic Vent Membrane Sweatproof For VR Headset Microphone
EPTFE VR Headset Microphone Sweatproof Acoustic Vent Membrane Product Overview This EPTFE acoustic vent membrane is purpose-built for Virtual Reality (VR) headsets, where microphones face constant exposure to sweat, heat, and condensation during physically active gaming and training sessions. The ...
EV Battery Pack Pressure Equalization Vent Bolt Waterproof Breathable Metal Threaded
EV Battery Pack Pressure Equalization Vent Bolt Waterproof Breathable Metal Threaded Product Overview The EV battery pack pressure equalization vent bolt is a critical safety component for electric vehicle battery enclosures. It combines a precision metal threaded body with a waterproof ePTFE ...
Medical Grade EPTFE Miniature Acoustic Vent Membrane For Hearing Aid Devices
Medical Grade EPTFE Miniature Acoustic Vent For Hearing Aid Devices Product Overview This medical-grade EPTFE miniature acoustic vent is purpose-designed for hearing aid devices, where acoustic transparency, biocompatibility, and long-term resistance to cerumen (earwax) and moisture are non...
White EPTFE Acoustic Vent Membrane for Automotive Hands Free Microphone Array
EPTFE Automotive Hands Free Microphone Array Acoustic Vent Membrane Product Overview This EPTFE acoustic vent membrane is specifically designed for in-vehicle hands-free microphone arrays mounted in headliners, overhead consoles, seatbelt assemblies, or integrated into the infotainment system. It ...
Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.